es Pressure Flow Controller AP100HC

The Pressure You Need
Electrically Controlled

Nurse holding the AP100HC

Electric Pressure Control
for Surgical Irrigation

The AP100HC is an electrically powered surgical irrigator. It pressurizes saline bags through dedicated pressure bags to deliver irrigation fluid for surgical site irrigation.

Two Lines
Independent Control

Set the required pressure for CH1 and CH2 separately. Start or pause pressurization on each channel independently.

Operating the AP100HC front panel

All Controls on
the Front Panel

Adjust pressure, start or pause pressurization, and release air using the buttons on the front panel.

View CH1 and CH2 pressure readings simultaneously on one screen, and check each channel's status as you operate the unit.

10–300 mmHg
in 5 mmHg Increments

300 mmHg

Maximum Set Pressure

AP100HC control panel for pressure adjustment and display

Two-Stage Protection
Against Excess Pressure

If pressure rises above the set range, the high-pressure alarm and overpressure protection activate in stages.

01

310 ±5 mmHg

High-Pressure Alarm

When high pressure is detected, visual and audible alarms activate, and pressurization on both channels stops automatically.

02

320 ±5 mmHg

Overpressure Protection

When overpressure is detected, the affected channel is automatically depressurized, and the other channel also stops automatically.

Connect the AP100HC
to Dedicated Pressure Bags

Connection Example

CH1

SPC

Dedicated Pressure Bag

SPC-1000 dedicated pressure bag shown in an AP100HC connection example

AP100HC

Pressure Flow Controller

es Pressure Flow Controller AP100HC unit

CH2

SPC

Dedicated Pressure Bag

SPC-2000 dedicated pressure bag shown in an AP100HC connection example

Three Sizes
for Different Needs

Select a size that matches the capacity of the saline bag you use.

SPC-500 dedicated pressure bag for the AP100HC

500 mL

SPC-500

ES-SPC-0500

SPC-1000 dedicated pressure bag for the AP100HC

1000 mL

SPC-1000

ES-SPC-1000

SPC-2000 dedicated pressure bag for the AP100HC

2000 mL

SPC-2000

ES-SPC-2000

The AP100HC cannot be used on its own.

Dedicated SPC Series pressure bags are required. The AP100HC comes with two tube connectors.

When ordering three or more pressure bags, you will need one additional tube connector for each bag beyond the first two.

2

bags

No Additional Connectors

3

bags

1 Additional Connector

4

bags

2 Additional Connectors

Repeatedly removing and reinserting the tube connector can cause the pressure bag tubing to deteriorate prematurely. Leave the connector attached unless removal is necessary.

Secure to an IV Pole
with the Rear Clamp

The rear C-shaped clamp fits poles up to approximately 25 mm in diameter (80 mm in circumference), as a guide.

C-shaped clamp on the back of the AP100HC

From Setup
to Pressurization

  1. 01

    Installation

    Secure the AP100HC to an IV pole or similar stand using the rear C-shaped clamp.

  2. 02

    Connections & Power

    Connect the AC adapter and tube connectors, then press and hold the power button to turn on the unit.

  3. 03

    Pressure Setting & Pressurization

    Set the required pressure using the pressure adjustment buttons, then press the pressurization/pause button to start pressurization.

  4. 04

    Air Release & Bag Replacement

    Use the exhaust/depressurization button to release air from the pressure bag. After replacing the saline bag, check the pressure setting and repressurize.

Features That Support Daily Use

Built-In Battery Operation

The unit operates on AC power or its built-in lithium-ion battery. A full charge provides at least 2 hours of continuous operation.

Previous Pressure Settings Saved

The pressure settings in use when the unit is turned off are saved in internal memory and restored when the unit is turned on again.

Watch the Operating Instructions

See the basic steps for connecting the unit, setting the pressure, and starting pressurization.

How the AP100HC
Is Used in Clinical Practice

Explore how healthcare facilities use the AP100HC, and hear from the healthcare professionals who work with it.

Illustrative image of healthcare professionals in an operating room
  • Clinical Use

    For which cases, procedures, or clinical situations do you use the AP100HC?

  • Changes After Adoption

    Has introducing the AP100HC improved surgical irrigation, pressurization, or equipment management?

AP100HC
Specifications

Review the unit specifications, power requirements, and medical device information.

Product Name es Pressure Flow Controller AP100HC
Generic Name (Japan) Electrically Powered Irrigator
Medical Device Classification (Japan) General Medical Device / Specially Designated Medical Device Requiring Maintenance
Notification No. (Japan) 13B2X00231001041
Pressure Range 10–300 mmHg
Pressure Adjustment Increment 5 mmHg
Channels 2 independently controlled channels
Display 2.8-inch LCD
Power Supply AC 100–240 V, 50/60 Hz
Internal Power Source Rechargeable lithium-ion battery
Rated 7.4 V / 2,500 mAh (18.5 Wh)
Unit Dimensions W 150 mm × D 69.5 mm × H 200 mm
With C-Shaped Clamp W 150 mm × D 105 mm × H 200 mm
Weight 1.1 kg
Protection Rating IP22
Operating Environment Ambient temperature: 5–30°C
Relative humidity: 15–80% RH (non-condensing)
Atmospheric pressure: 700–1060 hPa

AP100HC Maintenance

In Japan, the AP100HC is designated as a medical device requiring maintenance. To maintain its basic performance, annual maintenance inspections by the marketing authorization holder are recommended.

Service Life: 6 Years

Based on self-certification and company data, provided the specified maintenance inspections are properly performed.

Rechargeable Lithium-Ion Battery

Approximately 600 charging cycles, based on self-certification and company data.

From Pre-Purchase Checks
to Basic Operation

Find information on AP100HC operation, ordering requirements, and product specifications in the documents below.

Demo Program

Try the AP100HC
in Your Clinical Setting

AP100HC units prepared for demonstration

Demo units are available for the AP100HC. Please contact us with questions about specifications or operation, or to inquire about borrowing a demo unit.

This product is a medical device for use only by healthcare professionals, including physicians. It is intended for surgical site irrigation with saline and must not be used for intravascular infusion or blood transfusion. For details, refer to the package insert and instruction manual.